The Yocto-0-10V-R-C converts 0-10V Voltage to USB it measures the Voltage Values from any industrial sensor with 0-10V

- Channels:2
- USB connector:USB-C
- Refresh rate:50Hz
- Input impedance:10KΩ
- Measuring range:0…10V
- Accuracy:0.1%
- Resolution:0.001V
The 0-10V USB converter can record the measured values on its internal flash for later retrieval when connected again by USB. The device can automatically map the Voltage reading to the measurement units by applying a proportional rule. The module features two inputs, to connect two independent sensors.


Power the Sensor and Read the Voltage
The Yocto-0-10V-Rx provides up to 80mA to power sensors . The supply voltage is regulated 23V, isolated from the USB bus but common to both inputs.
Accuracy
- Accuracy:0.1%
- Resolution:0.001V
Dimensions
- Width:20mm
- Length:60mm
- Weight:10g
This device can be connected directly to an Ethernet network using a YoctoHub-Ethernet, to a WiFi network using a YoctoHub-Wireless-n and to a GSM network using a YoctoHub-GSM.
Yocto-0-10V-R-C Specifications
- Hardware release:Rev. D
- Product ID:RX010V1C
- Product name:Yocto-0-10V-Rx-C
- USB connector:USB-C
- Width:20mm
- Length:60mm
- Weight:10g
- Channels:2
- Refresh rate:50Hz
- Input impedance:10KΩ
- Measuring range:0…10V
- Accuracy:0.1%
- Resolution:0.001V
- Protection class, according to IEC 61140:class III
- USB isolation, dielectric strength:1kV
- Normal operating temperature:5…40°C
- Extended operating temperature2:-30…85°C
- Supported Operating Systems:Windows (PC + IoT), Linux (Intel + ARM), macOS, Android
- Drivers:Driverless, no driver needed
- API / SDK / Libraries:C++ Obj-C C# VB.NET UWP Delphi Python Java Android LabVIEW
- API / SDK / Libraries (TCP only):Javascript Node.js PHP#
RoHS compliance:RoHS III (2011/65/UE+2015/863) - Suggested enclosure:YoctoBox-Long-Thick-Black-Vents
- Harmonized tariff code:9032.9000
- Made in:Switzerland